Dimensions Length |
Dimensions Length
260mm/10.2inch |
Dimensions Width |
Dimensions Width
200mm/7.8inch |
Dimensions Height |
Dimensions Height
190mm/7.4inch |
Weight |
Weight
13kg/28.7lbs |
Housing Material |
Housing Material
Stainless Steel |
Terminal Model |
Terminal Model
M8 |
Internal Resistance |
Internal Resistance
≤20mΩ |
Nominal Voltage |
Nominal Voltage
12.8V |
Rated Capacity (0.2C) |
Rated Capacity (0.2C)
100Ah |
Efficiency |
Efficiency
99% |
Energy |
Energy
1280Wh |
Self Discharge |
Self Discharge
≤3% Per Month |
Charge Voltage |
Charge Voltage
14.4 ± 0.2V |
Maximum Charge Current |
Maximum Charge Current
100A |
Charge Cut-off Voltage |
Charge Cut-off Voltage
14.6V |
Maximum Continuous Discharge Current |
Maximum Continuous Discharge Current
100A |
Discharge Cut-off Voltage |
Discharge Cut-off Voltage
≥10V |
Discharge Temperature |
Discharge Temperature
-4 to 140 ºF (-20 to 60 ºC) |
Charge Temperature |
Charge Temperature
32 to 113 ºF (0 to 45 ºC) |
Storage Temperature |
Storage Temperature
23 to 95 ºF (-5 to 35 ºC) |
Charge Voltage |
Charge Voltage
DC:14.4V 3.6/Cell |
Balance Voltage(Single cell) |
Balance Voltage(Single cell)
14.4 V (3.6 ±0.025 vpc) |
Balance Current (single cell) |
Balance Current (single cell)
36±5mA |
Self-discharge current |
Self-discharge current
≤20μA |
Maximum continuous charge current |
Maximum continuous charge current
100A |
Peak discharge current |
Peak discharge current
200 A (7.5 s ±2.5 s) |
Overcharge detection voltage |
Overcharge detection voltage
15.6 V (3.9 ±0.025 vpc) |
Overcharge detection delay time |
Overcharge detection delay time
0.5S—2S |
Overcharge release voltage |
Overcharge release voltage
15.2 V (3.8 ±0.05 vpc) |
BMS Discharge Voltage Cut-Off |
BMS Discharge Voltage Cut-Off
8 V (2.0 ±0.08 vpc) (140 ±60 ms) |
Over-discharge detection delay time |
Over-discharge detection delay time
10mS—200mS |
Over-discharge release voltage |
Over-discharge release voltage
9.2 V (2.3 ±0.1 vpc) |
Over-current testing voltage |
Over-current testing voltage
0.10±0.015V |
BMS Discharge Current Cut-Off |
BMS Discharge Current Cut-Off
280 A ±50 A (9 ±4 ms) |
Over-current detection delay time |
Over-current detection delay time
5ms—20ms |
Protection release condition |
Protection release condition
Disconnected load |
Testing |
Testing
Short-circuit |
Detection delay time |
Detection delay time
200-500us |
Release condition |
Release condition
Disconnected load |
Balance threshold voltage |
Balance threshold voltage
14.4V |
Balance current |
Balance current
40±5mA |
Protection(MOSFET) |
Protection(MOSFET)
≤20mΩ |
Working Temperature |
Working Temperature
-40~+65℃ |
Storage Temperature |
Storage Temperature
-40~+125℃ |